Manual
POS4000
Document Number: POS4007 37
Document Title: POS4000/V2 WSII Operations Manual
[3] (password 3)
[MENU UP/DOWN] until "Multiple Unit MENU->" appears
[ENTER]
[MENU UP/DOWN] until "Controller/Remote" appears
[ENTER]
[2] to select Remote
[ENTER]
Note:
The default is for the console unit to be a controller.
4.1.11.3 Set Number of Bays and Consoles
This command is used to define the number of customer interfaces (carwash bays) and remote
POS4000s that are present at a site.
Note:
Do not include the controller POS4000 when counting the number of Remote
POS4000s.
To select this command, scroll through the Multiple Unit sub-menu until "Set # Bays/Consoles"
appears and then press [ENTER].
Example to setup a controller console to communicate with 2 customer interfaces and 1 remote
POS4000:
[CMD]
[SYSTEM SETUP]
[3] (password 3)
[MENU UP/DOWN] until "Multiple Unit MENU->" appears
[ENTER]
[MENU UP/DOWN] until "Set # Bays/Consoles" appears
[ENTER]
[2][ENTER] 2 bays
[1][ENTER] 1 remote console
Note:
The default is 1 bay and 0 remote consoles.
Note:
When setting up a remote console, # of remote consoles is always set to 0.
4.1.11.4 Program Remote Consoles
This command is used to program or download information from the controller POS4000 to
remote POS4000s.
To select this command, scroll through the Multiple Unit sub-menu until "Prog Remote Consoles"
appears and then press [ENTER].