Figure 10. Portal Mounting for Bricked-In Installation
2.4.3 Brick-in Guidelines
2.4.3.1 Using the Adapter Plate
The recommended procedure when mounting the Adaptor Plate directly to the brick
structure is as follow s:
1. Build the brick enclosure up to 36” high (8 rows of bricks) from t he pavement.
2. Fill the enclo sure with concrete.
3. Sink the Adaptor Plate with Mounting Bolts into the wet concrete. Position the
Adaptor Plate 4 ½” back from the front edge of the brick. Level the Adaptor Plate
while the concrete is st ill wet.
4. After the co ncrete has cur ed, secure the Portal TI t o the Adaptor Plate with the (3)
flat washers, lock washers and bolts supplied with the brick kit. Pull the wires up
through the cable entrance ports on the bottom of the Portal enclosure and finish
the brick structure.