Installation Manual Owner's manual
C-START
Document Number: CST1001 4
Figure 2. Conduit Runs
1.2.3 Wiring Requirements
Wiring requirements are summarized in the following table. As wires are pulled
through conduit, ensure there is at least 6 ft. of wire extending from the end of the
conduit stub. The Network (CAT-5) cable will need to be terminated with 8 position
RJ-45 connectors per Ethernet standard 568B.
Circuit Description Wire Qty Wire Description
Power (115-120 VAC, 8 Amps). 3 16 AWG (black/white/green)
Network connection (to router) 1 Cat 5 communications cable, 295 ft max length
Wash Control Varies Per wash equipment manufacturer’s instructions
Intercom (Optional) 2-4 22 AWG minimum, Qty varies by intercom model