User guide
Section 3: INSTALLATION
3-9
2. You then assign voice channel and DN numbers to the
e
ma-
GEN
ports.
3. Lastly, you physically connect
e
maGEN
-PC cards, via the
audio cable, junction box, and MDF, to the audio channels of the
OCD card MIM(s).
To mount the MIM on the OCD card, perform the following steps, as
shown in Figure 3-2, below:
1. Place the OCD card on a soft, clean surface (a piece of sponge
or cardboard) with the components facing up.
2. Select the position in which the MIM is to be attached to the
OCD card:
• 3, the upper position, with 20 and 64-pin connectors
J6 and J9, respectively;
• 2, the middle position, with 20 and 64-pin connectors
J5 and J8, respectively;
• 1, the lower position, with 20 and 64-pin connectors
J4 and J7, respectively.
3. Plug the MIM into the selected pair of 20 and 64-pin connectors.
4. Make sure the module is seated firmly against the OCD card.
5. Tighten the screw on the top of the module.
NOTE
The position in which the MIM is assigned
and mounted on the OCD card determines
which voice channels and which wires will
be dedicated to it for connection between
the
e
maGEN
-PC and the
unit
e
system
cabinet.