User guide

76-110-0887/0, Issue 1
12-6
If an unlimited recording time checked -- the next field below this --
the maximum message length field will remain blank.
Unlimited message length
For an unlimited recording time, check the unlimited message
length box.
Minimum message length
This is the minimum amount of recorded audio that
e
maGEN
will
consider to be a valid message.
Maximum silence during recording
When
e
maGEN
is recording a message, it listens for the silent
period when the caller stops speaking in order to determine when to
end the recording. If the silence period exceeds the value entered in
this field,
e
maGEN
will assume the caller has finished recording
the message.
e
maGEN
will then compress the silence period and
store the message.
Alert caller on end of recording
e
maGEN
will advise a caller leaving a message that the message
length is about to reach a pre set limit. This entry determines when
Legal values:
5 to 999 seconds
Default:
120 seconds
Action:
Enter the maximum recording time in
seconds.
Legal values:
Check
Default:
Unchecked
Action:
Check the unlimited message length box.
Legal values:
0 to 99 seconds
Default:
2 seconds
Action:
Enter the desired minimum recording time.
Legal values:
1 to 20 seconds
Default:
5 seconds
Action:
Enter the desired silence period for
message compression.