2. Emergency stop: The service lift shall not move
UP/DOWN. Release the emergency stop and drive
the lift UP approximately 1 m.
3. Press UP/DOWN buttons on the control box. The
lift should travel upwards or downwards.
6.3.3.2 CABIN CONTROL BOX:
1. ON/OFF button: Turn the ON/OFF button on the
user control box to the OFF position. The green light
shall be OFF. The service lift shall not run. Turn it ON;
the green light shall be on.
The service lift shall run.
2. Emergency stop: Press the emergency stop
button. The service lift shall not move UP/DOWN.
Release the emergency stop and drive the lift UP
approximately 1 m.
3. Fault light: Open the door or press the emergency
stop, the red fault light on the control box shall be on.
4. Top and bottom hatch: Open the hatch, the fault
light in red shall be ON and the lift shall not move UP/
DOWN.
5. Service lift door: Open the door, the fault light in
red shall be ON and the lift shall not move UP/DOWN.
6. Drive the service lift down until the bottom safety
stop hits the bottom mechanical stop. The lift shall
stop.
7. Drive the service lift up until the top safety stop
hits with the top mechanical stop.
8. Pull down the top hatch handle until the roof
switch is activated, the fault light in red shall be ON
and the lift shall not move.
6.4 Yearly inspection
6.4.1 Pinions
Check carefully that the pinions are free from
deterioration, damage or abrasion.
Wear limit:
To evaluate the wear of the pinion, “A” dimension
measured on the primitive line shall range between
24.41 and 25.7 mm.
Pinion replacement criteria is shown in table below:
DIMENSIONS NEW PINION
(mm)
CHANGE PINION
( mm)
A 25.70 < 24.41
6.4.2 Ladder rack
1. Check carefully that the rack is free from
deterioration, damage or abrasion.
2. Check that the ladder mast has no cracks, dents or
damages.
6.4.2.1 Wear limit:
1. Using a calibrated rod of Ø 12 and check that
dimension control “B”, as shown in the picture, is
between 32.69 and 34.59 mm. Measure the rack wear
on each mast section.
Rack replacement criteria is shown in table below:
DIMENSIONS NEW RACK
(mm)
CHANGE RACK
( mm)
B 34.59 < 32.69
2. Using two calibrated rods of
Ø 12 mm check that distance
between ladder sections dents
is 49.7 ± 0.5 mm.
6.4.2.2 Looseness limit:
To evaluate the looseness, check of control dimension
“C” shall be between 57 and 59 mm.
Rack replacement criteria is shown on table below:
DIMENSIONS NEW RACK
(mm)
CHANGE RACK
( mm)
C 57 > 59
PRIMITIVE
LINE
A (minimum)
24,41
A (nominal)
25.70
B
B
C (nominal)
C (loose)
57 59