3.19 Overload limiter
Electronic equipment is installed inside the cabin
control box. The overload detection system prevents
any movement of the service lift in the event of an
overload. In case of an overload, the overload light
(yellow) illuminates.
This system consists of a floating floor with four load
cells. The load cells send the load signal to the
electronic equipment.
3.20 Manual descent system
Each motor group features a hand lever, that allow
manual release of the motor electromagnetic brake.
Once the motor brakes are released, the service lift
descends with a controlled speed limited by the
centrifugal brake installed in each motor group.
3.21 Rest platforms
There is a rest platform at least every 6 metres. The
rest platforms are attached to the ladder on the ladder
section connection.
Rest platforms are self folding using torsion springs so
they do not interfere with the cabin movement when
they are not used.
3.22 Anchor points for PPE
The service lift is equipped with two anchor points
inside the cabin. In case of evacuation, the evacuation
procedure must be followed (see “Safety measures”).
F
FLOATING
FLOOR
CELLS
FIXED
FLOOR
BOTTOM
HATCH
TOP ANCHOR
POINT
BOTTOM
ANCHOR POINT
Push hand levers Upwards and downwards
At the same time to perform manual
descent and always look through
the perforated sheet holes.
STOP
Document Position
Serial number plate Cabin
Manual Cabin
Quick guide Cabin
Use of PPE label Cabin
Work load / Nº persons label Cabin
Warning risk of falling Cabin
Warning risk of crushing Cabin
Label emergency descent Cabin
Wiring diagram
Bottom platform
control box
Electric warning
disconnection label
Alignment labels Cabin and
each landing
Lubrication label Cabin
3.23 Information signs and documents
The following documents, signs and labels are
supplied with the service lift and shall always be
available.