Specifications

15
User’s, Installation and Maintenance Manual
!
3.9 Controls
3.9.1 Bottom platform control box
3.9.2 Cabin control box
UP/DOWN LIGHTS (GREEN)
Shines when the lift is going up
or down respectively.
FAULT LIGHT (RED)
Shines when there is an activated
switch on the safety circuit i.e:
Open door, emergency stop
pressed, open hatch or the ON/
OFF buttons of the user control
box is not in the ON position
EMERGENCY STOP
Press to interrupt any control
function. Turn/pull to reset the
control after necessary verifications
FAULT LIGHT (RED)
Shines when there is an activated
switch on the safety circuit i.e:
Open door, emergency stop
pressed, open hatch or the ON/OFF
buttons of the user control box is
not in the ON position.
OVERLOAD LIGHT (YELLOW)
Shines when the cabin is overload
EMERGENCY STOP
Press to interrupt any control
function. Turn/pull to reset the
control after necessary
verifications.
ON/OFF SELECTOR (GREEN)
Select ON position, then the control
box has electric current and the
light shines.
Select OFF position, then the
control box has not electric current
and the light does not shine.
TOP AND BOTTOM PLATFORM
LIGHT (GREEN)
Shines when the lift reaches the
bottom platform, top platform or
bottom / top stop bars are engaged.
UP/DOWN BUTTONS
Push continuously “UP” or “DOWN”
button, when you are inside the
cabin to go up or down.
READY LAMP (GREEN)
Shines when the box has
electric current.
DOWN BUTTON
Press down button to call the lift
to the bottom platform.
HOUR COUNTER
ON/OFF MAIN SWITCH
NOK
OK
User control box inside the cabin has control priority over control boxes at platforms.
This button has priority over any UP/
DOWN BUTTON at the platforms.
NOK