Measurement Range Accuracy Resolution
Outdoor Temperature -40 to 60 °C ± 1 °C 0.1 °C
Outdoor Humidity 10 to 99% ± 5% (only guaranteed
between 20 to 90%)
1 %
UV Index 1 to 15+ ± 1 ± 1
Sunlight 0 to 200klux ± 15% ± 15%
Rain 0 to 6553.5
mm
<15mm:±1 mm,
15mm to 6553.5
mm:±7%
<1000mm (0.3mm)
>1000mm (1mm)
Wind Direction 0 - 360 º
45º (8 point compass) 45º (8 point
compass)
Wind Speed 0 to 50 m/s 2 m/s ~10 m/s: ±3m/s,
10m/s ~50 m/s: ±10%
(whichever is greater)
0.1 m/s
6.3 Power Consumption
Integrated Outdoor Transmitter: 3xAA alkaline batteries or Lithium batteries (not
included)
Battery life:
Minimum 12 months for Integrated Outdoor Transmitter (use lithium batteries in
cold weather climates less than -20 °C), The primary power source is the solar
panel. The batteries provide backup power when there is limited solar energy
7.Maintenance
1. Clean the rain gauge and wind transmitter once every 3 months.
Unscrew the rain collector funnel by turning it 30°counter clockwise.
Gently remove the rain collector funnel.
Clean and remove any debris or insects.
Install the collector funnel after it has been cleaned and completely dried.
Figure 58