Cut Sheet

Technical Datasheets
R
A H I LT I G R O U P C O M PA N Y
Properties Units SolarMount SolarMount HD
Beam Height in 2.5 3.0
Approximate Weight (per linear ft) plf 0.811 1.271
Total Cross Sectional Area in² 0.676 1.059
Section Modulus (X-Axis) in
3
0.353 0.898
Section Modulus (Y-Axis) in
3
0.113 0.221
Moment of Inertia (X-Axis) in
4
0.464 1.450
Moment of Inertia (Y-Axis) in
4
0.044 0.267
Radius of Gyration (X-Axis) in 0.289 1.170
Radius of Gyration (Y-Axis) in 0.254 0.502
1.316
.387
2.500
.750
SLOT FOR T-BOLT OR
1
4" HEX HEAD SCREW
2X SLOT FOR
BOTTOM CLIP
SLOT FOR
3
8" HEX BOLT
SLOT FOR T-BOLT OR
1
4" HEX HEAD SCREW
1.385
SLOT FOR
BOTTOM CLIP
SLOT FOR
3
8" HEX BOLT
1.875
3.000
1.207
Y
1.728
SolarMount Beams
SolarMount Beam
SolarMount HD Beam
Dimensionsspeciedininchesunlessnoted
Y
X
Y
X
4