Quick Mount PV SolarHook Installation Guide
Table Of Contents
OPTIONAL SUB-FLASHING
INSTALLATION GUIDE
5
APPLY FLASHING TO ROOF UNDERLAYMENT
Place the synthetic flashing over the entire
tile hook base. Press or roll the flexible
flashing strips onto the roof underlayment
ensuring full contact and removal of any
bubbles or wrinkles.
APPLY UP-SLOPE FLASHING STRIPS
Prepare Up-Slope Flexible Flashing
Strips. Cut two 4 inch X 16 inch strips of
flexible flashing. Apply first upslope strip
horizontally over the edge of the
synthetic flashing. 50% of the flashing
strip should be on the roof
underlayment.
APPLY UP-SLOPE FLASHING STRIPS & COMPLETE INSTALLATION
Apply second up-slope strip horizontally over the edge of the first up-slope strip. The
second strip should overlap the first, with 50% of the flashing strip on the roof
underlayment. Press or roll the flexible flashing strips onto the roof underlayment
ensuring full contact and removal of any bubbles or wrinkles.
CLEAN UNDERLAYMENT
Underlayment surface should be dry and
free of dirt or other debris that would
prevent adhesion of flexible flashing.
PREPARE SYNTHETIC FLASHING
Cut a piece of synthetic underlayment to
a 6 inch X 11 inch rectangle.
PREPARE FLEXIBLE FLASHING STRIPS
Cut two 4 inch X 8 inch strips of flexible
flashing. Apply strips along short
edge of synthetic flashing with 50% of
the flexible flashing strip exposed for
attachment to the roof underlayment.
MATERIALS REQUIRED:
• (Qty 1) 6 inch X 11 inch synthetic underlayment
• (Qty 2) 4 inch X 8 inch flexible flashing strip
• (Qty 2) 4 inch X 16 inch flexible flashing strip
• Stiff bristle brush
• Knife or scissors
• Roller (optional)
NOTES:
•Unirac recommends using an
aluminum backed butyl flexible flashing
tape.
• Refer flexible flashing manufacturer’s
instructions and technical data for
surface compatibility, preparation,
primer requirements, and
environmental limitations.