Install Manual
Table Of Contents
SOLARHOOKS
PAGE
12
PRO SERIES INSTALLATION GUIDE
DESIGN RULES
Allowable
Spans (in.)
Portrait
Modules
Landscape
Modul es
Portrait
Modules
Landscape
Modul es
Portrait
Modules
Landscape
Modul es
72
13.4 22.1 12.2 12.2 12.9 21.3
60
16.1 26.6 8.9 14.6 15.5 25.6
48
20.1 33.2 11.1 18.3 19.4 32.0
36
26.8 44.3 14.8 24.4 25.8 42.6
24
40.2 66.4 22.2 36.5 38.8 64.0
12
80.5 132.8 44.3 73.1 77.5 127.9
DownSlope
Lateral
AT1 Allowable Pressure (psf)
UP
Allowable
Spans (in.)
Portrait
Modules
Landscape
Modul es
Portrait
Modules
Landscape
Modul es
Portrait
Modules
Landscape
Modul es
72
16.6 27.4 7.4 12.2 12.9 21.3
60
19.9 32.9 8.9 14.6 15.5 25.6
48
24.9 41.1 11.1 18.3 19.4 32.0
36
33.2 54.8 14.8 24.4 25.8 42.6
24
49.8 82.2 22.2 36.5 38.8 64.0
12
99.7 164.5 44.3 73.1 77.5 127.9
DownSlope
Lateral
UP
CT1 Allowable Pressure (psf)
Allowable
Spans (in.)
Portrait
Modules
Landscape
Modul es
Portrait
Modules
Landscape
Modul es
Portrait
Modules
Landscape
Modul es
72
14.0 23.1 7.4 12.2 12.9 21.3
60
16.8 27.8 8.9 14.6 15.5 25.6
48
21.0 34.7 11.1 18.3 19.4 32.0
36
28.1 46.3 14.8 24.4 25.8 42.6
24
42.1 69.4 22.2 36.5 38.8 64.0
12
84.2 138.9 44.3 73.1 77.5 127.9
UP
DownSlope
Lateral
CT2 Allowable Pressure (psf)
Allowable
Spans (in.)
Portrait
Modules
Landscape
Modul es
Portrait
Modules
Landscape
Modul es
Portrait
Modules
Landscape
Modul es
72
16.6 27.4 5.7 9.4 2.4 4.0
60
19.9 32.9 6.9 11.3 2.9 4.8
48
24.9 41.1 8.6 14.2 3.6 5.9
36
33.2 54.8 11.4 18.9 4.8 7.9
24
49.8 82.2 17.2 28.3 7.2 11.9
12
99.7 164.5 34.3 56.6 14.4 23.8
UP
DownSlope
Lateral
CT5 Allowable Pressure (psf)
HOOK TYPE UP/DOWN DOWNSLOPE LATERAL
AT1 218 120 210
CT5 270 93 39
CT1 270 120 210
CT2 228 120 210
ASSUMPTIONS AND USE DETAILS
• Pressure limits refer to Up, Down, Downslope, and Lateral PSF
• Pressure limits apply to all roof zones
• Solarhooks not recommended for use in hurricane zones
• See pressure table appendix for representative geographic pressures or refer to Unirac
Pressure Tables for Flush Mounted Systems on unirac.com
• Allowable Loads:
PRESSURE LIMIT MODIFICATION GUIDELINES
• Portrait Module Height 65 inches
• Landscape Module Width 39.4 inches
• Pressure limits provided above were calculated utilizing a B module size of 39.4in wide x 65in
long
• These pressure limits may be increased or decreased linearly.
• To modify pressure limits provided, follow these simple steps:
1. For portrait modules, multiply the given pressure limit by (65" / New Module Length)
2. For landscape modules, multiply the given pressure limit by (39.5" / New Module Width)