SOLARHOOKS PRO SERIES SOLARHOOK FLAT TILE 004AT1H TABLE OF CONTENTS Getting Started Flat Tile Hook Installation Universal Hook Installation Spanish Hook Installation Sub Flashing Spec Sheets and Details Design Rules Pressure Tables SOLARHOOK UNIVERSAL W/ ADJUSTABLE BASE 004CT5H PAGE 2 3 4 5 6 7-11 12 13 1 INSTALLATION GUIDE INSTALLATION GUIDE PAGE SOLARHOOK SPANISH 7” FIXED BASE 004CT1H SOLARHOOK SPANISH 9” FIXED BASE 004CT2H
SOLARHOOKS PRO SERIES GETTING STARTED 2 INSTALLATION GUIDE PAGE ROOF HOOK CAPACITIES AND ENGINEERING Refer to engineering report tables for tested allowable loads. Refer to local AHJ to determine the correct code (ASCE 7-05, 7-10 or 7-16) and environmental loads. It is the responsibility of the installer to ensure these mounting attachments are appropriate for the application. Please contact your 3rd party engineer for more information.
SOLARHOOKS PRO SERIES 1. Remove tiles around installation area. 2. Locate and mark rafters. UNIVERSAL 3 INSTALLATION GUIDE PAGE 3. Position hook, adjusting arm-base bolt position as needed. Use 3/16” bit to drill 2 pilot holes. 4. Remove hook, clean debris and fill pilot holes with roofing sealant Torque arm-base nut to 16 ft. lbs. NOTE: SOLARHOOK UNIVERSAL is compatible with all tile profiles. Installation process is the same for all profiles. 5. Reposition hook, secure with included lag screws.
SOLARHOOKS PRO SERIES 1. Remove tiles around installation area. 2. Locate and mark rafters. FLAT 4 INSTALLATION GUIDE PAGE 3. Position hook. Use 3/16” bit to drill 2 pilot holes. 4. Remove hook, clean debris, then fill pilot holes and rib on back of hook with roofing sealant. RECOMMENDED TOOLS Drill, Impact Driver 3/16” drill bit Sealant Marking crayon/ chalk Rafter locator 5. Reposition hook, secure with included lag screws. 6. Replace tiles, if necessary notch with grinder to ensure proper fit.
SOLARHOOKS PRO SERIES 1. Remove tiles around installation area. 2. Locate and mark rafters. SPANISH 5 INSTALLATION GUIDE PAGE 3. Position hook. Use 3/16” bit to drill 2 pilot holes. 4. Remove hook, clean debris and fill pilot holes with roofing sealant NOTE: SOLARHOOK SPANISH CT1 and CT2 are compatible with W and S tile profiles. Installation process is the same for both tile profiles and hook models. 5. Reposition hook, secure with included lag screws. 6.
SOLARHOOKS DESIGN RULES INSTALLATION GUIDE PAGE PRO SERIES ASSUMPTIONS AND USE DETAILS • Pressure limits refer to Up, Down, Downslope, and Lateral PSF • Pressure limits apply to all roof zones • Solarhooks not recommended for use in hurricane zones • See pressure table appendix for representative geographic pressures or refer to Unirac Pressure Tables for Flush Mounted Systems on unirac.
SOLARHOOK STAINLESS STEEL APPENDIX PRESSURE TABLES 11
SOLARHOOK STAINLESS STEEL APPENDIX PRESSURE TABLES 12
SOLARHOOK STAINLESS STEEL APPENDIX PRESSURE TABLES 13
SOLARHOOK STAINLESS STEEL APPENDIX PRESSURE TABLES 14
SOLARHOOK STAINLESS STEEL APPENDIX PRESSURE TABLES 15
SOLARHOOK STAINLESS STEEL APPENDIX PRESSURE TABLES 16