Check all connectors in the complete freezer LP gas system for gas leaks. The LP
gas supply must be turned on. Apply a non-corrosive bubble solution to all LP
connections. The appearance of bubbles indicates a leak and should be repaired
immediately by a qualified serviceman.
WARNING DO NOT USE FLAME TO CHECK FOR GAS LEAKS
PROCEDURE FOR CLEANING THE COOLING SYSTEM FLUE
WARNING: Carbon Monoxide can be hazardous to your health. Gas appliances
may emit excessive Carbon Monoxide if the freezer’s burner, burner orifice, and the
flue tube are not regularly cleaned. To prevent Carbon Monoxide, the burner, burner
orifice, and the cooling system’s flue tube must be cleaned at least once a year and
after all prolonged (seasonal) shut-down periods. Refer to the following cleaning
procedures, or contact a qualified installer or your dealer for more information
1. Before cleaning, cover the burner to protect it from dirt;
2. Remove the freezer from its enclosure.
3. Remove the spiral flue baffle from the flue tube.
4. Using a stiff brush or fine emery cloth, clean the spiral flue baffle of debris.
5. Clean the inside of the flue tube with the flue brush provided. Inspect burner
after cleaning.
6. Re-install the spiral flue baffle. Insure the spiral flue baffle is securely in place. The
spiral flue baffle is required for efficient cooling while operating in the gas mode.
CLEANING AND INSPECTION OF THE BURNER
Take off the burner cover and do the following:
1. Clean the openings and the burner tube with a wire brush and pipe cleaner.
2. Clean and inspect the electrode and thermocouple. If either is corroded, have
it replaced. Check that they are well attached and if necessary tighten the
screws