18.  Locate the burner tube and locate the retaining screw at the front of the tube. 
Once this screw has been removed, lift up the burner and pull away slightly to the 
right to expose the oven orifice. 
19.  With a 7mm wrench or pliers remove the orifice and replace with NG orifice. 
20.  Replace the burner tube, then start up the oven to check oven flame, making sure 
21.
22.
it’s tight and blue
. Adjust the air shutter at the back of the burner tube to achieve 
this. Once you have the bottom pan and oven door closed, and with the broiler 
drawer  pulled  down,  you  will  be  able  to  see  how  the  flame  should  look  by 
viewing the flame through the broiler door area. 
Orifice
Wrench 
U N I Q U E   U G P 3 0 G  
In the pilot assembly shown below, the LPG orifice is 0.14 mm. When doing
the conversion from Propane to Natural
gas make sure the pilot orifice is 
changed to the NG orifice sized at 0.2 mm. If you leave the LPG orifice 
0.14mm in place, the pilot flame will may be too small to keep the pilot lit
. 
Pilot Orifice
Oven Orifice 
Check for leaks using a leak detector or soapy water with recommended ratio 
of 75% water, 25% dish washing soap.
Once you have completed the conversion, check the operations of ignition 
making sure each of the 4 burners, pilot flame and oven burner flame are 
functioning correctly. Pleases refer to pages 19 through 22