Installation Guide

UNIQUE UGP 3
7
5. Release the safety device control (D) and again check to see that the flame is
alight, making sure the needle is in the green area of the flame indicator.
6. Adjust the thermostat knob (E) to desired temperature setting and allow for
6 to 8 hours of operation to achieve desired temperature.
Shut Down Procedure – LP Gas
1. To terminate gas operation, turn selector switch (A) to either OFF or AC (110V)
position.
2. Shut the gas off at the LP-gas supply cylinder when the appliance is not in use.
3. If the refrigerator will not be in operation for a period of weeks, it should be emptied,
defrosted, cleaned and the doors left open. The ice tray should also be dried and kept
outside the cabinet.
110V Operation
1. Make sure that the gas valve is turned off at the tank.
2. Ensure the electrical cord is plugged into a grounded outlet
3. Turn the selector switch (A) to AC (110V) position.
4. Adjust the thermostat knob (E) to desired temperature setting and allow for 6 to
8 hours of operation to achieve desired temperature.
12V DC Operation
Set the power selector knob (A) to DC mode. See right fig. The DC mode is only designed to be
used when driving, otherwise your battery will be discharged within a few hours!
On 12V DC operation the fridge will only maintain temperature already achieved. .
1. If 110 Volts or LP gas is not available, the refrigerator can work with DC12V
(3-Way models only).
2. Make sure that you turn the main power switch (A) to AC (110V) position.
This will allow the heating element to work, you can then connect the
12VDC power cord (not supplied) to the terminal block located at the upper
right side of the refrigerator, while facing the back.
3. DC operation is not as efficient as LP Gas or AC operation. DC electric
should not be used to initially cool the refrigerator. Only use DC when the
other modes are unavailable (for example; while in transit). When you start to
use AC or gas supply, make sure that you disconnect the DC power input.