Warranty

UNIQUE UGP 3
5
B. Option - Outdoor use only
Connecting of Gas Supply
A. Indoor and Outdoor use only
1. Use supplied #600 connector, regulator and hose to connect your appliance to the
gas supply #3.
2. Tighten #3 to #600 regulator assembly
3. and #4 using a backup wrench to the appliance.
4. After connecting, all
gas connections must be checked for leaks
. For this, put
a soapy solution on all gas connections, turn on the gas cylinder manual valve and
watch for bubbles. Never use an open flame to check for leaks.
Note: The gas supply system must incorporate a pressure regulator to maintain a supply
pressure of not more than 12” water column and no less than 11” water column. (Max
setting)
B. Outdoor use only
5. Use optional or supplied regulator and hose to connect your appliance to the gas
supply.
6. Hook up the 5/8”-18UNF connection to the back of your appliance using a
backup wrench.
7. Attach the regulator cap to the tank inlet connection and ensure it is tight.
8. After connecting, all
gas connections must be checked for leaks
. For this, put
a soapy solution on all gas connections, turn on the gas cylinder manual valve and
watch for bubbles. Never use an open flame to check for leaks.
Note: The gas supply system must incorporate a pressure regulator to maintain a supply
pressure of not more than 13” water column and no less than 11” water column. (Max
setting)
A.
Indoor and Outdoor us
e