Warranty
UNIQUE UGP 3
6
General Operating Instructions
Importance of Leveling a Refrigerator
The refrigerator must be adjusted to a vertical position in both directions. In an
absorption refrigeration system, ammonia is liquefied in the finned condenser coil at the
top rear of the refrigerator. The liquid ammonia then flows into the Evaporator (inside
the freezer section) and is exposed to circulating flow of hydrogen gas, which causes the
ammonia to evaporate, creating a cold condition in the freezer.
When starting this refrigerator, the cooling cycle may require 6 to 8 hours of running time
to begin cooling before the cooling unit is fully operational, you can then begin slowly
loading the compartment.
The tubing in the evaporator section is specifically sloped to provide a continuous
movement of liquid ammonia, flowing downward by gravity through this section. If the
refrigerator is operated when not level, liquid ammonia will accumulate in sections of the
evaporator tubing. This will slow the circulation of hydrogen and ammonia gas, or in
severe cases, completely block it, resulting in a loss of cooling. Warranty will not cover
recharge/rebuild if caused by not running the fridge level.
This refrigerator operates LP Gas (Propane), 110V (Electricity) and 12V DC
The power selector has 5 positions
Gas Operation
“Start Up” Procedure
After initial installation, servicing, or changing gas cylinders etc., the gas pipes may
contain some air which should be allowed to escape by briefly turning on the
refrigerator. This will ensure that the flame lights immediately.
1. Make sure that all valves between the gas container and the refrigerator are
open.
2. Turn selector switch (A) to gas.
3. Depress the safety device control (D) and hold it down while immediately
depressing the electronic igniter button (B)
4. Once the flame indicator (C) starts to move into the green, release the
electronic igniter button (B) but continue to keep the safety device control
(D) depressed for a further 10-15 seconds.