Installation Guide
17
U N I Q U E   U G P 2 4 G  
10. Remove all LPG orifices: place in the bag and store in a safe place. 
11.  Take the NG orifices provided and install them as shown below  
See below for rating of orifice for each model 
  Smallest  Medium x 2  Largest  Oven 
NG  0.8 mm  1.5 mm  1.65 mm  1.8 mm 
12. Once all the orifices are installed, replace all burners and burner caps, then fire up 
the burners to check the minimum flame height.  
13. Minimum flame height should be approx. ¼” tall. There is a small adjustment 
screw located on the valve itself. The lid and the front control panel must be 
removed to accomplish this adjustment. 
14. Turn the valve fully counter clockwise.  Then proceed to adjust the adjustment 
screw counter  clockwise  for a smaller  flame  and clockwise  for  a larger  flame. 
Adjustment: Minimum flame should be approx. ¼” tall 
Orifice Location 
Adjustment location is 
inside the valve stem 
Burner Orifice
Flame Height Adjustment
15. Temporarily replace the lid, burners, burner caps and grates and recheck the flame. 
Once complete, reassemble the control panel and the lid. 
16. Next, the oven orifice needs to be replaced. 
17. Remove all racks, then the bottom pan by lifting up the back first to release the 
front then pull pan out. 