Installation Guide
                
11 
The appliance must be isolated from the gas supply piping system by closing its 
individual manual shut-off valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/2 psig. 
WALL CLEARANCES 
All units must be installed in accordance to minimum rear and side wall clearance 
and clearances extended vertically above cooking top which are stated on the serial 
plate. (The serial plate is located on the bottom of the broiler cavity.) 
ANY OPENINGS IN THE WALL BEHIND THE UNIT AND IN THE FLOOR 
UNDER THE UNIT MUST BE SEALED. 
Note. Due to potential hazards it is recommended that storage cabinets not be 
installed above the cooking surface. 
IN THE EVENT OVERHEAD CABINETS ARE INSTALLED, THE 
MAXIMUM DEPTH OF CABINETS INSTALLED ABOVE COOKING TOPS 
SHOULD BE 13”. 