Use and Care Guide
14 
Warning - DO NOT use a pin or wire when 
cleaning the burner orifice as damage can occur to 
the precision opening. This can cause damage to 
the refrigerator or create a fire hazard. It will also 
create  extremely dangerous levels of carbon 
monoxide. 
o  The inlet & outlet gas fittings on the refrigerator need to be checked 
for leaks. Apply a non-corrosive bubble solution to the fittings and 
observe for leaks. The safety valve will not allow gas pressure to any 
connections between it and the burner orifice. These fittings must be 
checked while burner is in operation (gas flow will be present between 
safety valve and burner head). 
WARNING – The gas button D (Fig. #5) must be 
manually depressed to allow gas pressure to flow to the 
burner orifice. Be sure to apply the leak check solution 
before depressing the safety shut–off. DO NOT allow 
any open flame, sparks, smoking, etc. in the area of the 
test. DO NOT depress safety shut-off for over 30 seconds. 
o  If a leak occurs, then allow ten minutes to dissipate from the burner 
area. Fix leak then light the burner according to the instructions under 
GENERAL OPERATING INSTRUCTIONS – GAS OPERATION, CHAPTER 3. 