Use and Care Guide
13 
Check burner flame for proper appearance. The flame should be light blue with no 
yellow at the tip. See figure #6
•  The LP gas pressure should be checked and the main regulator readjusted if 
pressure is incorrect. The correct operating pressure is 11” W.C. (water 
column). 
•  Inspect the flue baffle, it should be clean and free of soot. Any soot formation 
indicates improper functioning of the burner. The flue and burner both 
require cleaning in the following manner: 
o 
Remove cover from the burner housing. 
o 
Remove the burner by removing the burner mounting screw 
o 
Remove the wire and flue baffle from the top of flue tube. Clean the 
flue from the top using a flue brush and be sure to cover the burner 
if remaining intact to eliminate dirt falling into the burner. Blowing 
compressed air into the flue should clean out soot and scale. Replace 
the flue baffle.
o 
Clean burner tube with compressed air, check for fluff or spider webs. 
o 
Before removing burner orifice, clean burner area of any soot, scale or 
dirt. Remove the orifice/burner jet and soak it in alcohol (isopropyl 
alcohol or thinners) and blow it out with compressed air. Re-install 
and tighten burner orifice.
o  Replace burner 
Fig. #6 
Fig. #7 
Burner Mounting Screw 
Burner Jet/Orifice 