DC POWER CONNECTION continued
ATTENTION
If a longer connection cable is necessary, the cable cross section
(or gauge) must be equal to or greater than the cable sizes recom-
mended on the following table. Be careful that the input voltage at
the appliance does not drop below the cut-out voltage of the com-
pressor.
LOW VOLTAGE DISCONNECT
The compressor electronics includes a low voltage disconnect
feature. If the input voltage to the appliance falls below 22.8V the
compressor will shut-o. Once the voltage increases above 24.2V
the compressor will resume normal operation.
This feature is designed to protect the system battery from experi-
encing too low a depth of discharge.
CABLE SIZE 24V CABLE
LENGTH
AREA AWG
mm
2
/inch Gauge m ft
4 /
5
/
32
”
12 2.5 8
6 /
15
/
64
”
10 5 16
10 /
25
/
34
”
8 8 26 (Max length/run)
24 V OPERATION
SHUT-OFF 22.8 V
RESTART 24.2 V