510 L / 18 cu. ft.
UNIQUE UGP-18F Propane Refrigerator Installation and Owner’s Manual The installation of the appliance must conform with local codes or, in the absence of local codes, to the national Fuel Gas Code, ANSI Z233.1 and in Canada B149.
MANUFACTURED AND CERTIFIED BY Unique Gas Products Ltd “Personal Service & Knowledge makes us Unique” 2245 Wyecroft Road Oakville, Ontario Canada L6L 5L7 Ph: 905-827-6154 Toll Free: 1-877-427-2266 Fax: 905-827-2027 www.UniqueOffGrid.com E-mail: info@uniqueoffgrid.
Table of Contents Chapters Welcome 1 Safety & Warnings ` 1 Appliance Installation 2 General Operating Instructions 3 How To Use The Refrigerator 3 Maintenance & Service 4 Troubleshooting & Suggested Spares 5 Carbon Monoxide Instructions (CM Model) 6 Temperature Controls & Food Storage and Cleaning 7 Parts & Warranty 8
1 Chapter U G P - 1 8 F Welcome & Congratulations C ongratulations on your purchase of a UNIQUE refrigerator!. We are very proud of our product and we are completely committed to providing you with the best service possible. Your satisfaction is our #1 priority. Please read this manual very carefully. It contains valuable information on how to properly maintain your new gas refrigerator. We know you will enjoy your new refrigerator and Thank You for choosing one of our Unique Gas Products.
U G P - 1 8 F Please mail in the Warranty Registration Card included with your refrigerator or you can register online at www.uniqueoffgrid.
U G P - 1 8 F Warning • • Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. This product can produce Carbon Monoxide. Carbon Monoxide has no odour and can kill you. The burner and flue system must be kept clean. See owner’s manual for cleaning instructions.
2 Chapter U G P - 1 8 F Installation For best performance at high ambient temperatures, there must be free air circulation over the cooling unit at the rear of the refrigerator. Ensure that there is a free air space above the refrigerator and that the flue (chimney) on top of the cabinet is not covered in any way. Do not place the refrigerator in a space where air circulation is restricted. Follow “clearance” instructions.
U G P - 1 8 F Clearances Minimum clearances to combustible materials are: Top – 10” Sides – 2” Rear – 1” with left hand side rear shield mounted as shown in Figures. 1,2 & 3. Note: DO NOT install the appliance directly on carpeting. Carpeting must be removed or protected by a metal or wood panel beneath the appliance, which extends at least the full width and depth of the appliance.
U G P - 1 8 F Gas Connection Hook-up to the gas supply line: 3/8” SAE (UNF 5/8” - 18) male flare connection. A backup wrench must be used when tightening gas supply fitting. All completed connections should be checked for leaks with a non-corrosive leak detector and/or soap and water for a bubble check.
3 Chapter U G P - 1 8 F General Operating Instructions Importance of Leveling a Refrigerator The refrigerator must be adjusted to a horizontal position in both directions. In an absorption refrigeration system, ammonia is liquefied in the finned condenser coil at the top rear of the refrigerator. The liquid ammonia then flows into the evaporator (inside the freezer section) and is exposed to circulating flow of hydrogen gas, which causes the ammonia to evaporate, creating a cold condition in the freezer.
U G P - 1 8 F Gas Operation “Start Up” Procedure – see Figure # 5 on next page for control panel 1. Locate the control panel below at the bottom front of fridge 2. Turn the gas shut off valve C to the ON position – to the left 3. Turn thermostat button B fully clockwise (Max), start to spark igniter button A before depressing the gas control button E, there may be a period of time required for air to escape from the gas line and flow up to burner.
U G P - 1 8 F CONTROLS – See Fig 5. for description of controls Figure #5 Thermostat A thermostat controls the refrigerator cooling temperature; it can be adjusted by turning knob B to different settings to maintain the desired refrigerator temperature. Knob E also incorporates a safety device, which automatically shuts off the supply of gas if the flame goes out. The piezo electric igniter discharges sparks onto the burner when the button is pushed. 1.
U G P - 1 8 F How to Use the Refrigerator FOOD STORAGE COMPARTMENT The food storage compartment is completely closed and unventilated, which is necessary to maintain the required low temperature for food storage. The coldest areas in the refrigerator are under the cooling fins and at the bottom of the refrigerator. The warmer areas are on the upper door shelves. This should be considered when placing different types of food in the refrigerator.
U G P - 1 8 F Cleaning Cleaning the refrigerator is usually done after it is defrosted or put into storage. To clean the interior liner of the refrigerator, use lukewarm dish soap solution. Use only warm water to clean the finned evaporator, gasket, ice trays and shelves. Never use strong chemicals or abrasives to clean these parts as the protective surfaces will be damaged. It is important to always keep the refrigerator clean. Dish soap is recommended.
4 Chapter U G P - 1 8 F Maintiance & Service The user should be aware of service that must be done on a regular schedule to keep the refrigerator operating properly. Installation must be by a licensed gas fitter in accordance with local codes or in the absence of local national Fuel Gas Code, ANSI Z233.1 and in Canada B149.2 Propane Storage and Handling Code (latest edition). REFRIGERATOR REMOVAL Before working on the refrigerator, shut off the gas supply.
U G P - 1 8 F • Check all connectors in the complete refrigerator LP gas system for gas leaks. The LP gas supply must be turned on. Apply a non corrosive bubble solution to all LP connections. The appearance of bubbles indicates a leak and should be repaired immediately by a qualified serviceman. WARNING – DO NOT USE FLAME TO CHECK FOR GAS LEAKS Check burner flame for proper appearance. The flame should be light blue with no yellow at the tip. See figure #6 Fig. #6 Fig.
U G P - 1 8 F o o o burner if remaining intact to eliminate dirt falling into burner. Replace the flue baffle. Clean burner tube with compressed air, check for fluff or spider webs. Before removing burner orifice, clean burner area of any soot, scale or dirt. Remove the orifice and soak it in alcohol (isopropyl alcohol or thinners) and blow it out with compressed air. Re-install and tighten burner orifice.
U G P - 1 8 F o If leak occurs, then allow ten minutes to dissipate from the burner area.
5 Chapter U G P - 1 8 F TROUBLESHOOTING INSTRUCTIONS & SUGGESTED SPARE PARTS TO KEEP ON HAND REFRIGERATOR DOES NOT COOL, CHECK LIKELY CAUSES: 1. Burner orifice clogged. Clean. See section Maintenance & Service, CHAPTER 4, Item #2. Periodic Maintenance, Items 1-9. 2. Check to ensure refrigerator is level – (left to right and front to back). 3. Restriction on air flow across cooling unit. 4. Heavy frost build up on evaporator fins. Defrost. 5. Flue baffle not inserted properly in flue tube. 6.
U G P - 1 8 F Spare Parts The following is a list of commonly used parts which are available: • Burner orifice • Burner • Electrode • Thermocouple • Safety valve & thermostat • Piezo igniter (push button) • Baffle Contact your dealer or an authorized service center for parts and repairs as needed. Quote Model & Serial # - See CSA rating/serial plate on inside left wall.
6 Chapter U G P - 1 8 F Carbon Monoxide Monitor Instructions for Model UGP-18F OWNER’S MANUAL Model 9RV-SSO Carbon Monoxide Alarm for Appliance Safety Shutoff ATTENTION: PLEASE READ, FOLLOW AND SAVE! (See Additional Instruction Sheet for Safety Shutoff Connection) Dear New COSTAR 9RV-SSO Owner, Congratulations as you have taken steps to help ensure the health and safety of you and your family.
U G P - 1 8 F DATE” printed on the alarm cover may result in death by Carbon Monoxide poisoning. Replace by date is six (6) years from date of manufacture. 1.0 WHAT YOU SHOULD KNOW ABOUT CO Carbon monoxide (CO) is an insidious poison. It is a colorless, odorless and tasteless gas. It is a cumulative poison.
U G P - 1 8 F concentrations under 30 ppm. 2.0 WHAT YOU SHOULD DO IF THE ALARM SOUNDS WARNING: Activation of this device indicates the presence of carbon monoxide (CO) which can KILL YOU. If alarm sounds: For users in the United States, follow the protocol in steps 1 through 4 below: 1 Operate reset/silence button; 2 Call your emergency services (____ - ______) [fire department or 911]; 3 Immediately move to fresh air – outdoors or by an open door/window.
U G P - 1 8 F 2.1 IMPORTANT CONSIDERATIONS: The COSTAR 9RV-SSO has been designed and is warranted to operate for six years. Never disconnect the battery to silence an alarm. The alarm will automatically sense when the level of CO in the air falls below the danger level. You should stay outside the residence, or unconditioned area and remain in fresh air until the alarm is silenced. When the alarm sounds, do not stand too close to the alarm.
U G P - 1 8 F assistance from outside your residence. – Know where to go to call the emergency service provider and or a qualified service technician. 4.0 IMPORTANT: WHAT YOUR CO ALARM CAN AND CANNOT DO 4.1 This unit is designed to detect carbon monoxide (CO) and shutoff an appliance for safety only. 4.2 This CO alarm is designed for use within a single residential living unit. It is designed to detect carbon monoxide (CO) entering its sensing chamber.
U G P - 1 8 F WALL LOCATION: Mount the alarm at least 3 feet (usually 5 – 6 feet) from the floor. Figure 1: Recommended CO alarm wall mounting location is 5 to 6 feet from floor 5.3 LOCATIONS TO AVOID: Nuisance alarms are caused by placing units where they will not operate properly. To avoid nuisance alarms, do not place units: – Within 5 feet (1.5m) of any cooking appliance or furnace. – Near an open window or door, because the fresh air entering the opening may delay CO from reaching the alarm.
U G P - 1 8 F 3 Simultaneous operation of several fuel burning appliances competing for limited internal air. 4 Vent pipe connections vibrating loose from clothes dryers, furnaces, refrigerators, or water heaters. 5 Obstructions in or unconventional vent pipe designs which can amplify the above situations. 6.0 5.4.2 Extended operation of un-vented fuel burning devices (range, oven, fireplace, etc.) 5.4.3 Temperature inversions, which can trap, exhaust gasses near the ground. 5.4.
U G P - 1 8 F Step A: Wall Alignment Step B: Alarm Activation Step C: Removal and Installation Figure 2: Installation Instructions 6.3 To insure aesthetic alignment of the alarm with the hallway or wall, the UP arrow on the mounting plate must be vertical when wall mounting: (See Step A in Figure 2) 6.4 As described in Figure 2, attach the mounting plate on the wall. Use the screws and anchors provided to secure the mounting plate. 6.5 The battery is INSTALLED REVERSED FOR SHIPPING.
U G P - 1 8 F Figure 3). Note the tamper resist pin will have to be removed in order to change the battery; this can be done easily with a long nose pliers. Using the long nose pliers pull the pin out of the hole, it is now possible to remove the alarm from the mounting plate. Figure 3: Tamper Resistant Locking Pin 6.8 This box contains two self-adhesive labels. You should write the telephone numbers of the emergency service provider and a qualified technician in the space provided on the labels.
U G P - 1 8 F 8.0 MAINTENANCE CLEANING YOUR ALARM: 8.1. Keep your CO alarms clean – use a damp (water only) cloth or vacuum. 8.2. To clean your alarm, remove it from the mounting bracket as outlined in Figure 2 Step D: Installation/Removal. IF TAMPER RESISTANT PIN HAS BEEN USED, REFER TO STEP 6.7 UNDER INSTALLATION INSTRUCTIONS FOR REMOVAL INSTRUCTIONS. (See Figure 3) 8.
U G P - 1 8 F They can be purchased anywhere batteries are sold, such as your local hardware store. 9.3 USE ONLY THE FOLLOWING 9 VOLT BATTERY FOR CO ALARM REPLACEMENT: Alkaline type: DURACELL: MN1604 WARNING USE ONLY THE BATTERY SPECIFIED. USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE CO ALARM. THE CONSTANT EXPOSURES TO HIGH OR LOW TEMPERATURES OR HIGH HUMIDITY MAY REDUCE BATTERY LIFE. CHECK THE BATTERY MANUFACTURERS SPECIFICATIONS FOR PROPER OPERATING CONDITIONS.
7 Chapter U G P - 1 8 F Temperature Controls Note: Maximum setting is override; therefore the thermostat function is not operational at this setting. This setting is usually only required during very hot and humid days. COOL DOWN PERIOD To ensure safe food storage, allow the refrigerator to operate with the doors closed for at least 8 hours before loading it with food.
U G P - 1 8 F Looking Inside SHELF ADJUSTMENT Refrigerator shelves are easily adjusted to suit individual needs. Before adjusting the shelves, remove all food. Simply slide shelf to the right to release from inserts and relocate to another position available on the wall of the cabinet. Note the top shelf is cut smaller due to the evaporator plate depth. Food Storage Ideas FRESH FOOD STORAGE • • The refrigerator should be kept between 38° F and 40° F (3.3° C and 4.
U G P - 1 8 F NOTES: Do not use razor blades or other sharp instruments, which can scratch the appliance surface when removing adhesive labels. Any glue left from tape or labels can be removed with a mixture of warm water and mild detergent, or, touch the glue residue with the sticky side of tape you have already removed. Do not remove the certification/serial plate, lighting instructions or CO warning label.
8 Chapter U G P - 1 8 F Parts Diagram and List 32
U G P - 1 8 F 33
U G P - 1 8 F Burner Train Assembly 34
U G P - 1 8 F UNIQUE UGP 18F Fridge Item# PART# DESCRIPTION 1 UGP18F-01 PANEL – OUTER DOOR WHITE 2 UGP18F-02 BUNG 3 UGP18F-03 UNIQUE NAME PLATE 4 UGP18F-04 HANDLE MOUNTING SCREW 5 UGP18F-05 SET SCREW 6 UGP18F-06 DOOR HANDLE 7 UGP18F-07 PLUG – BOTTOM DOOR 8 UGP18F-08 DOOR STOP 9 UGP18F-09 SCREW – DOOR STOP 10 UGP18F-10 DOOR CLOSER 11 UGP18F-11 SCREW 12 UGP18F-12 CLIP - PANEL 13 UGP18F-13 GASKET BRACKET 14 UGP18F-14 DOOR RACK 15 UGP18F-15 INNER DOOR PANEL 16 U
U G P - 1 8 F Item# PART# DESCRIPTION 25 UGP18F-25 TRIVET 26 UGP18F-26 WIRE SHELF - SMALL 14.50 X 23.88 27 UGP18F-27 WIRE SHELF – LARGE 16.69 X 23.
U G P - 1 8 F Item# PART# DESCRIPTION 48 UGP-9RV-SS0 CO DETECTOR 9RV SSO 49 QMP-INTERRUPTER BODY INTERRUPTER BLOCK FOR CO-MONITORED FRIDGES 50 QMP-18-FET MOSFET ASSY - FOR CO-MONITORED MODELS 37
U G P - 1 8 F UNIQUE UGP18F 5 YEAR LIMITED WARRANTY* Unique Gas Products Ltd. warrants that this UNIQUE refrigerator is free from defects in material and workmanship under normal usage and service under the following terms: 1. 2. 3. This Warranty is made only to the first purchaser (”original purchaser”) who acquires this refrigerator for his/her own use and will be honored by Unique Gas Products Ltd. and by the Seller. Any part of this refrigerator returned to the Seller or Unique Gas Products Ltd.
U G P - 1 8 F LIMITED WARRANTY COSTAR Model 9RV-SSO UNIQUE GAS PRODUCTS LTD offers you this limited warranty on your new carbon monoxide alarm, including all of its component parts except the battery. This limited warranty extends solely to the original end-user purchaser of this product, provided your purchase was made from an authorized vendor. Transfer or resale of this product will automatically terminate warranty coverage. UNIQUE GAS PRODUCTS LTD.