User's Manual
Chapter 3 Installation
3.6.3 Unpacking
Inspect
all crates, cabinets and boxes for exterior damage and make note of any dents,
broken seals, or other indications of improper handling. In the event any in transit damage is
discovered, report it to UBS.
The control and HPA cabinets will be wrapped in shrink-wrap with cardboard corner
protection and will be secured to a pallet with four (4) bolts. Remove the shrink-wrap and
cardboard corner protectors; do not discard the cardboard corner protectors.
Open/remove the front and rear doors/panels on the cabinets and inspect the interiors for
packing material and carefully remove any material that is found. Do not remove any
labeling or tags from the cabinets, drawers/modules, wires/cables or connectors; these are
identification markers that make assembly of the repeater system much easier.
The OFN cabinet will be wrapped in shrink-wrap with cardboard corner protection and will be
secured to a pallet with eight (8) bolts. Remove the shrink-wrap and cardboard corner
protectors; do not discard the cardboard corner protectors.
Three (3) other pallets will include the components which need to be installed in the
repeater cabinets on-site. The components have been sorted by cabinet prior to shipping.
Remove the components from their pallet and boxes. Verify that all materials are enclosed
as listed on the packing slip and report any shortages to UBS.
NOTE: The HPA’s will be sorted on the pallets and each HPA will be marked, indicating
which HPA compartment slot (0, 1, 2, 3, 4, 5, 6 or 7) it should be installed in.
3.6.4
Installation Surface
The load b
e
aring strength of the roof or floor where the repeater cabinets will be placed
should be taken into consideration. The repeater cabinets weigh approximately 3300 lbs.
combined, and rest on an area of 31.55 square feet of roof or floor space.
Before installing the repeater cabinets, check the installation surface structure, flatness and
suitability.
SX03-30000-01-M01
3-10