User's Manual
Chapter 2 System Description
2.4.6 Power Supply
Power Supply
Control Cabinet Voltage 208 – 240 VAC,
Single Phase, 4 wire (L1, L2, N, G)
HPA Cabinet Voltage 208 – 240 VAC,
3-Phase, 4 wire Delta or Y (L1, L2, L3, N, G)
Frequency 47 to 63 Hz
Power Consumption Overall: max. 36 kVA
Control Cabinet: 2 kVA
HB HPA Cabinet: 17 kVA
LB HPA Cabinet: 17 kVA
2.4.7 Environmental
Environmental
Ambient Operating Temperature 32°F to +131°F (0°C to +55°C)
Ambient Storage Temperature -22°F to +167°F (-30ºC to +75ºC)
Operating Humidity 5% to 95%, non-condensing
Storage Humidity 5% to 99%, non-condensing
Altitude max. 5500 ft. (1676 m)
Control Cabinet Cooling Forced air
HPA Cabinet Cooling Forced air, 3100 CFM
Total DRU Heat Dissipation 97,000 BTU (Exhausted + Radiated)
Note: Radiated heat (into room) is equal to
15% of dissipated heat.
2.4.8 Mechanical
Mechanical (Overall)
Width 77.0 in. (195.58 cm)
Depth 59.0 in. (149.86 cm)
Height 102.4 in. (260.10 cm)
Weight (fully populated) Combined DRU: 3300 lbs. (1497 kg)
Independent DRU: 3400 lbs. (1542 kg)
SX03-30000-01-M01
2-47