User's Manual
Chapter 4 Commissioning
19. Switch ON the TRMS circuit breaker (CB1), located on the control cabinet PDU.
o Ensure that the TRMS Power LED is illuminated green.
20. Switch ON the FAN (CB4) circuit breaker, located on the HB HPA cabinet PDU.
o Ensure that the HB HPA cabinet fan/blower is rotating continuously (fan/blower can
be heard).
21. Switch ON the FAN (CB4) circuit breaker, located on the LB HPA cabinet PDU.
o Ensure that the LB HPA cabinet fan/blower is rotating continuously (fan/blower can
be heard).
22. Switch ON the HPA 0 PSU circuit breaker (CB0), located on the HB HPA cabinet PDU.
o Ensure that the HB HPA 1 PSU (PS 0) Norm LED is blinking green.
o Ensure that the HB HPA 1 PDU (PS 0) Alarm LED is blinking red.
23. Switch ON the HPA 1 PSU circuit breaker (CB1), located on the HB HPA cabinet PDU.
o Ensure that the HB HPA 2 PSU (PS 1) Norm LED is blinking green.
o Ensure that the HB HPA 2 PDU (PS 1) Alarm LED is blinking red.
24. Switch ON the HPA 2 PSU circuit breaker (CB2), located on the HB HPA cabinet PDU.
o Ensure that the HB HPA 3 PSU (PS 2) Norm LED is blinking green.
o Ensure that the HB HPA 3 PDU (PS 2) Alarm LED is blinking red.
25. Switch ON the HPA 3 PSU circuit breaker (CB3), located on the HB HPA cabinet PDU.
o Ensure that the HB HPA 4 PSU (PS 3) Norm LED is blinking green.
o Ensure that the HB HPA 4 PDU (PS 3) Alarm LED is blinking red.
26. Switch ON the HPA 4 PSU circuit breaker (CB4), located on the HB HPA cabinet PDU.
o Ensure that the HB HPA 5 PSU (PS 4) Norm LED is blinking green.
o Ensure that the HB HPA 5 PDU (PS 4) Alarm LED is blinking red.
27. Switch ON the HPA 5 PSU circuit breaker (CB5), located on the HB HPA cabinet PDU.
o Ensure that the HB HPA 6 PSU (PS 5) Norm LED is blinking green.
o Ensure that the HB HPA 6 PDU (PS 5) Alarm LED is blinking red.
28. Switch ON the HPA 6 PSU circuit breaker (CB6), located on the HB HPA cabinet PDU.
o Ensure that the HB HPA 7 PSU (PS 6) Norm LED is blinking green.
o Ensure that the HB HPA 7 PDU (PS 6) Alarm LED is blinking red.
29. Switch ON t
h
e HPA 7 PSU circuit breaker (CB7), located on the HB HPA cabinet PDU.
o Ensure that the HB HPA 8 PSU (PS 7) Norm LED is blinking green.
o Ensure that the HB HPA 8 PDU (PS 7) Alarm LED is blinking red.
30. Switch ON the HPA 0 PSU circuit breaker (CB0), located on the LB HPA cabinet PDU.
o Ensure that the LB HPA 1 PSU (PS 0) Norm LED is blinking green.
o Ensure that the LB HPA 1 PDU (PS 0) Alarm LED is blinking red.
31. Switch ON the HPA 1 PSU circuit breaker (CB1), located on the LB HPA cabinet PDU.
o Ensure that the LB HPA 2 PSU (PS 1) Norm LED is blinking green.
o Ensure that the LB HPA 2 PDU (PS 1) Alarm LED is blinking red.
SX03-30000-01-M01