Chapter 3 Installation
Figure 3-52 Indepentent DRU RF Output Ports
1) Output 1 (Combined RF Output Port) – WR340 Flange
2) Output 2 (Independent RF Output Port ) – WR340 Flange
3.14.2 Terminating a WR3 40 Flange Output
The following steps sho
u
ld be performed to terminate a WR340 flange output:
1. Place a WR340 half gasket (UBS p/n SX03-24101-02) into the WR340 flange groove
– see Figure 3-53
.
2. Connect the transmission line to the WR340 flange according to site drawings.
3. Secure the transmission line in place by installing a 1/4-20x7/8” socket head cap
screw with #12 flat washer and 1/4” lock washer in each of the threaded holes (10
total) – see Figure 3-53
. A torque rating of 45 Inch Lbs. must be used to tighten the
1/4-20 socket head cap screws.