Chapter 3 Installation
3.10.4.2 Independent DRU
D
uring the installation procedure, a number of cables must be connected between the
control cabinet bulkhead panel and components located in the OFN cabinet.
1. Cable SX03-33912-02 must be connected between BC14 and the DRU transmit output
coupler #1 “FWD 61dB” sample port – see Figure 3-42
.
2. Cable SX03-33928-02 must be connected between BC15 and the DRU transmit output
coupler #2 “FWD 61dB” sample port – see Figure 3-43
.
3. Cable SX03-33903-02 must be connected between BC13 and the DRU transmit output
coupler #2 DB-9 serial port – see Figure 3-42
.
4. Cable SX03-33929-02 must be connected between BC16 and the DRU transmit output
coupler #1 DB-9 serial port – see Figure 3-43
.
5. Cable SX03-33940-02 must be connected between BC27 the LBD WG transmit output
filter RF input – see Figure 3-44
.