Chapter 3 Installation
3.10.2 Control Cabinet to HB HPA Cabinet
D
uring the installation procedure, a number of cables must be connected between the
control cabinet bulkhead panel and HB HPA cabinet bulkhead panel. Please refer to Table
3-11
or drawings SX03-30900-02-D06 or SX03-30900-03-D06.
Figure 3-39 HB HPA Cabinet Bulkhead
PICTURE TBD
Table 3-11 Control Cabinet to HB HPA Cabinet Cable Connections
Control Cabinet Port/Type HB HPA Cabinet Port/Type Cable Number
BC26: 3-pos Circular (F) BH7: 3-pos Circular (M) SX03-33925-01
BC22: DB-9 (F) BH6: DB-9 (M) SX03-33936-01
BC6: SMA (F), 50 ohm BH1: SMA (F), 50 ohm SX03-33921-01
BC7: SMA (F), 50 ohm BH2: SMA (F), 50 ohm SX03-33921-01
BC8: DB-9 (F) BH3: DB-9 (M) SX03-33918-01
BC9: 3-pos Circular (F) BH4: 3-pos Circular (M) SX03-33925-01
BC10: 3-pos Circular (F) BH5: 3-pos Circular (M) SX03-33925-01
SX03-30000-01-M01