Chapter 3 Installation
3.9 Control Cabinet Internal Wire/Cable Connections
Once the 1
2V batter, HBE, LBE TRMS and dial-up modem (where applicable) are mounted in
the control cabinet, a number of wires/cables must be connected to these components.
NOTE: The cables will be bundled together using cable ties. Cut only the orange cable ties;
do not cut the white cable ties unless instructed.
Any RF cable, which is terminated with a SMA connector, should be
tightened with a 5/16” torque wrench (set to 7-8 Inch Lbs.) to avoid
over tightening and damaging the cable connector or mating connector.
3.9.1 Ground and AC Connections
All con
t
rol cabinet internal ground wires are pre-wired to the cabinet ground bar. During
the installation procedure, several components must be connected to the ground bar via the
pre-wired ground wires. Please see the subsequent sections of this manual.
All control cabinet internal AC components are pre-wired to the cabinet PDU. Only the
cabinet PDU needs to be connected to building/site electrical service panel (or AC disconnect
device).