User's Manual
Table Of Contents
- 1.0 INTRODUCTION
- 2.0 FEATURES & OPTIONS
- 3.0 SAFETY WARNINGS
- 4.0 WARRANTY (summary)
- 5.0 UNPACKING AND INSPECTION
- 6.0 GENERAL SPECIFICATIONS
- 7.0 PRINCIPAL OF OPERATION
- 8.0 FRONT PANEL DESCRIPTION
- 9.0 REAR PANEL DESCRIPTION
- 10.0 LED Indicators
- 11.0 MAKING CONNECTIONS TO THE X75
- 12.0 INSTALLATION
- 13.0 USING THE CONTROLLER WEB BROWSER INTERFACE
- Appendix 1 – SNMPv3 MIB Information
- Appendix 2 – Load LVD (special order)
- Appendix 3 – Revision History
- Figure 1 - X75 Compact Integrated DC Power System
- Figure 2 - Block Schematic
- Figure 3a - Front View with Breakers (configuration A)
- Figure 3b - Front View with GMT Fuses (configuration B)
- Figure 4 - Rear Views of Base and Expansion Units
- Figure 5 - LED Indicators
- Figure 6 - Recommended Load Circuit Wire Sizes
- Figure 7 - Battery Temp. Probe & Alarm Relay Connector Pin-Out
- Figure 8 - Ethernet Connector Pin-Out
- Figure 9 - Auxiliary Connector Pin-Out
- Figure 10 - Input Current Ratings
- Figure 11 - Status WEB Page (typical)
- Figure 12 - Rectifier Status WEB Applet (typical)
- Figure 13 - Installation WEB Applet - system tab (typical)
- Figure 14 - Installation WEB Applet - float & tc tab (typical)
- Figure 15 - Installation WEB Applet - battery tab (typical)
- Figure 16 - Installation WEB Applet - float & tc tab (typical)
- Figure 17 - Installation WEB Applet - lvd tab (typical)
- Figure 18 - Installation WEB Applet - digital i/p tab (typical)
- Figure 19 - Installation WEB Applet - rectifiers tab (typical)
- Figure 20 - Installation WEB Applet - shunts tab (typical)
- Figure 21 - Battery Management WEB Applet (typical)
- Figure 22 - Alarm Matrix WEB Applet (typical)
- Figure 23 - Alarm Matrix WEB Applet - matrix options (typical)
- Figure 24 - Alarm Matrix WEB Applet - temperature alarm settings (typical)
- Figure 25 - Alarm Matrix WEB Applet - voltage alarm settings (typical)
- Figure 26 - Alarm Matrix WEB Applet - voltage alarm settings (typical)
- Figure 27 - Alarm Matrix WEB Applet - other alarm settings (typical)
- Figure 28 - Network Settings WEB Applet (typical)
- Figure 29 - Alarm Log WEB Applet (typical)
- Figure 30 - Data Log WEB Applet (typical)
- Figure 31 - Change Password WEB Applet
- Figure 32 - Help WEB Page
- Figure 33 - About WEB Page (typical)
Page 55
X75 SERIES - Mk3 Controller
INSTALLATION & OPERATING MANUAL
Manual No. x75mk3-11
x75-man-Rev11-0815.indd
Parameter Name Function
rectierOCA Rectier over current alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
loadOCA Load over current alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
batteryOCA Battery over current alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
batteryODA Battery on discharge alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
digitalAlarmx
(x = 1 to 16)
Digital input x alarm. [1 only in X75]
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
nRectAlarm Insufcient rectiers alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
acfAlarm AC Failure alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
rectThermalAlarm Rectier thermal alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
rectFanAlarm Rectier fan alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
singleRFA Single rectier failure alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
multiRFA Multiple rectier failure alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
eqAlarm Equalization active alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
bTestAlarm Battery test active alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
bProbexDisAlarm
(x = 1 or 2)
Battery temperature probe x disconnected alarm. [1 only in X75]
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
bProbexShortAlarm
(x = 1 or 2)
Battery temperature probe x shorted alarm. [1 only in X75]
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
extProbeDisAlarm External temperature probe disconnected alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
extProbeShortAlarm External temperature probe shorted alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
bTestFailAlarm Battery test failure alarm.
(0) CLEAR, (1) OTHER, (2) MINOR, (3) MAJOR.
digitalInputx
(x = 1 to 16)
Digital input is Closed (0) or Open (1). [1 only in X75]