User's Manual
Table Of Contents
- 1.0 INTRODUCTION
- 2.0 FEATURES & OPTIONS
- 3.0 SAFETY WARNINGS
- 4.0 WARRANTY (summary)
- 5.0 UNPACKING AND INSPECTION
- 6.0 GENERAL SPECIFICATIONS
- 7.0 PRINCIPAL OF OPERATION
- 8.0 FRONT PANEL DESCRIPTION
- 9.0 REAR PANEL DESCRIPTION
- 10.0 LED Indicators
- 11.0 MAKING CONNECTIONS TO THE X75
- 12.0 INSTALLATION
- 13.0 USING THE CONTROLLER WEB BROWSER INTERFACE
- Appendix 1 – SNMPv3 MIB Information
- Appendix 2 – Load LVD (special order)
- Appendix 3 – Revision History
- Figure 1 - X75 Compact Integrated DC Power System
- Figure 2 - Block Schematic
- Figure 3a - Front View with Breakers (configuration A)
- Figure 3b - Front View with GMT Fuses (configuration B)
- Figure 4 - Rear Views of Base and Expansion Units
- Figure 5 - LED Indicators
- Figure 6 - Recommended Load Circuit Wire Sizes
- Figure 7 - Battery Temp. Probe & Alarm Relay Connector Pin-Out
- Figure 8 - Ethernet Connector Pin-Out
- Figure 9 - Auxiliary Connector Pin-Out
- Figure 10 - Input Current Ratings
- Figure 11 - Status WEB Page (typical)
- Figure 12 - Rectifier Status WEB Applet (typical)
- Figure 13 - Installation WEB Applet - system tab (typical)
- Figure 14 - Installation WEB Applet - float & tc tab (typical)
- Figure 15 - Installation WEB Applet - battery tab (typical)
- Figure 16 - Installation WEB Applet - float & tc tab (typical)
- Figure 17 - Installation WEB Applet - lvd tab (typical)
- Figure 18 - Installation WEB Applet - digital i/p tab (typical)
- Figure 19 - Installation WEB Applet - rectifiers tab (typical)
- Figure 20 - Installation WEB Applet - shunts tab (typical)
- Figure 21 - Battery Management WEB Applet (typical)
- Figure 22 - Alarm Matrix WEB Applet (typical)
- Figure 23 - Alarm Matrix WEB Applet - matrix options (typical)
- Figure 24 - Alarm Matrix WEB Applet - temperature alarm settings (typical)
- Figure 25 - Alarm Matrix WEB Applet - voltage alarm settings (typical)
- Figure 26 - Alarm Matrix WEB Applet - voltage alarm settings (typical)
- Figure 27 - Alarm Matrix WEB Applet - other alarm settings (typical)
- Figure 28 - Network Settings WEB Applet (typical)
- Figure 29 - Alarm Log WEB Applet (typical)
- Figure 30 - Data Log WEB Applet (typical)
- Figure 31 - Change Password WEB Applet
- Figure 32 - Help WEB Page
- Figure 33 - About WEB Page (typical)
Page 11
X75 SERIES - Mk3 Controller
INSTALLATION & OPERATING MANUAL
Manual No. x75mk3-11
x75-man-Rev11-0815.indd
8.0 FRONT PANEL DESCRIPTION
I
0
1 2 3
LOAD BREAKERS
I
0
I
0
I
0
I
0
CTR
MAJA
MINA
ACFA
RFA
OTA
OVA
CTR
MAJA
MINA
ACFA
RFA
OTA
OVA
12345
GMT FUSES
1.............................10
1 2 3
Figure3a-FrontViewwithBreakers(congurationA)
I
0
1 2 3
LOAD BREAKERS
I
0
I
0
I
0
I
0
CTR
MAJA
MINA
ACFA
RFA
OTA
OVA
CTR
MAJA
MINA
ACFA
RFA
OTA
OVA
12345
GMT FUSES
1.............................10
1 2 3
Figure3b-FrontViewwithGMTFuses(congurationB)
Figures 3a and 3b show the two system congurations as viewed from the front with breakers
and fuses respectively. Following is a description of each section.
8.1 From left to right there are 3 rectier slots. Each slot can accept one rectier from
the Sigma Series rated up to 650W output power. Only identical model rectiers of
appropriate output voltage may be installed at the same time. For example, a nominal
-48V system may contain between 1 and 3 model RSG48/10-Z OR between 1 and
3 model RSG48/12-Z but not a mixture of the two types.
8.2 To the right of the rectiers are 7 LED indicators which display various status and
alarm conditions. These are described in more detail in section 10.
8.3 On the right hand side of the unit is the DC distribution section which may contain
between 1 and 5 circuit breakers (conguration A) or a 10-way GMT fuse block
(conguration B).