User's Manual Part 1

Chapter 3 Installation
3.9.4 Terrestrial Repeater Monitoring System (TRMS)
During the installation procedure, a number of wires/cables must be connected to the TRMS
rear panel. Please refer to Table 3-8
or drawing SX03-10900-03-D06.
The cables should be connected in the order that they appear in Table 3-8
.
Any RF cable, which is terminated with a SMA connector, should be
tightened with a 5/16” torque wrench to avoid over tightening and
damaging the cable connector or mating connector.
Figure 3-28 TRMS Rear Panel
Table 3-8 TRMS Rear Panel Connections
TRMS Port Name Type Cable Number
N/A N/A Ground Post SX03-10926-07
Y1B RF-IN SMA (F), 50 ohm SX03-10908-07
Y2B RF IN SMA (F), 50 ohm SX03-10908-05
Y9B LAN RJ-45 SX03-10905-03
Y10A WAN RJ-45 SX03-10905-01
Y12 N/A
(AC Input)
NEMA Socket Polarized Type IEC
603
SX03-10913-01
SX03-10000-01-M01 3-34