User's Manual Part 1
Chapter 3 Installation
4. There are five (5) 7/8” blind mate connectors located on the DR filter box rear panel
which are aligned with corresponding connectors on the HPA compartment frame
backplane – see Figure 3-17
. Ensure that the connectors are aligned properly and
slowly push the DR filter box into the backplane until it stops. At this point, the back
side of the DR filter box front panel should be flush with the HPA compartment frame.
5. Secure the DR filter box in place by tightening the four (4) 10-32 Phillips head captive
screws (2 located on the top and 2 located on the bottom of the DR filter box) with a
torque rating of 19.2 Inch Lbs. – see Figure 3-18
.
Figure 3-17 Independent DR Filter Box Rear Panel
1) Slider
2) 7/8” Blind Mate Connector
SX03-10000-01-M01 3-22