Use and Care Manual

22
GAS RANGE CONVERSION (continued)
Convertible Pressure Regulator
The range is shipped to operate on LPG. NG orices and a special screwdriver for
adjusting the minimum ame are shipped with the unit in a separate envelope with
the manual. The inlet pressure of the gas supply shall be in accordance with the
nominal inlet pressure of the regulator used on the range or 1/2 psig maximum.
The range should be tested by pressurizing the regulator with an inlet pressure at
least 1 inch water column above the manufacturers specied manifold pressure
shown on the serial plate.
1. CAUTION: Before proceeding with the conversion, shut off the gas supply
to the appliance prior to disconnecting the electrical power (if applicable).
2. Locate convertible regulator at the back of the range, left side facing
appliance. Remove cap and pop out the pin that’s attached
3. On the side you will see the pin position for use with LPG
4. Unscrew pin and ip it to the NG position – long end outwards, spring on
inside.
5. Below is an example of additional positions depending on regulator type
installed.
9,000
3,000
9,000
10,000
13,000
44,000
9,000
3,000
9,000
10,000
13,000
44,000
Manifold Pressure: Natural Gas: 4” WC / LP/Propane: 10” WC
Electrical Rating: 1.5V DC. 1.0 A
LPG NG