Use and Care Manual

21
To Convert and/or Adjust to Natural Gas
The range is set for use with Lique ed Petroleum (LP). The factory setting
is indicated on the serial plate. When set for LP Gas operation, the pressure
regulator will regulate the gas to 10 inches water column pressure. When set for
Natural Gas operation, the pressure regulator will regulate the pressure to 4 inches
water column.
Liquid Propane Gas Conversion to Natural Gas
The conversion kit must be installed by quali ed service agency.
GAS RANGE CONVERSION
WARNING
“This conversion kit shall be installed by a quali ed service agency in
accordance with the manufacturer’s instructions and all applicable codes and
requirements of the authority having jurisdiction. If the information in these
instructions is not followed exactly, a  re, explosion or production of carbon
monoxide may result in property damage, personal injury or loss of life. The
quali ed service agency is responsible for the proper installation of this kit.
The installation is not proper and complete until the operation of the converted
appliances is checked as speci ed in the manufacturer’s instructions supplied
with the kit.”
2.
UGP-30G OF1
NOZZLE (NG)
RL
1.35
1.35
0.8
1.5
RR
FL FR
OVEN
1.9
1.
3. 4.
Parts List:
1. Nozzles
2. Tool Card
3. Tool
4. Pilot Ori ce
Model Number:
UGP 30CR OF1
UGP 30CR OF1
1.36
FL
RL
FR
RR
NOZZLE (NG)
OVEN
0.8
1.36
1.88
1.51