7 
 “Start-Up” Procedure 
Electronic Ignition (battery) 
1.  To start the refrigerator, turn the thermostat knob E to the maximum setting, #4. 
2.  Turn button G to “Gas” position, then push B button in first and hold, proceed to 
push in and hold the D button until you see the needle on the flame sensor C 
moving from the red into the green area. Release the B button, while continuing to 
hold in the D button for an additional 10-15 seconds, now release the D button. 
The burner should now stay on indicated by the needle staying in the green area, if 
not repeat the lighting instructions above. 
3.  Adjust the thermostat knob E to desired temperature setting after 8 or more 
hours of operation. 
4.  To change the battery in the electronic ignition, turn the far left knob A to the 
left to expose the battery, remove AAA battery and replace with a new one, 
positive outwards, replace the knob by turning to the right to close. 
Shut Down Procedure – Gas Operation 
1.  Turn selector knob G to the OFF position 
2. 
Shut the gas off at the LP-gas supply cylinder when the appliance is not in use. 
3.  If the refrigerator will not be in operation for a period of weeks, it should be 
emptied, defrosted, cleaned and the door left open.  
110V Operation 
1.  Ensure the electrical cord is plugged into a grounded outlet 
2.  Turn the selector switch G to AC position, AC power indicator F will 
illuminate 
3.  To start the refrigerator, turn the thermostat knob E to the maximum setting. 
4.  Adjust the thermostat knob to desired temperature setting after 8 hours of 
operation. 
CONTROLS – See Fig. #5 for a description of controls 