5 
connections should be checked for leaks with a non-corrosive leak detector and/or 
soap and water for a bubble check. 
  WARNING – DO NOT USE FLAME TO CHECK FOR GAS LEAKS 
The gas supply system must incorporate a pressure regulator to maintain a supply 
pressure of not more than 12” water column and no less than 11” water column (max 
setting). 
Make sure the refrigerator and any other high BTU appliances on your line are turned 
on when checking the gas pressure. The appliance and its individual shut-off valve 
must be disconnected from the gas supply piping system during any pressure testing of 
that system at pressures in excess of ½” psig. 
In case detailed instructions on the installation and connection of the gas supply are 
required, contact your dealer or distributor. 
Leveling 
Ensure the fridge is level by using a 2ft level. Level the fridge front to back and 
left to right using the top of the appliance. There are no leveling legs at the back 
of the appliance just at the front; if the back if your floor is uneven you will have 
to use shims of some sort to ensure the appliance is level. See the importance of 
leveling explained on next page. 