Specifications

4. For greater use of the printer
27
Select the print format of data.
13 types of print format can be selected.
Name of setting 07: Print Every Format
Selection item 0. Standard (initial value)
1. With time
2. With code
3. With time & code
4. With date
5. With date & code
6. Diagram
7. Double size
8. Double print
9. Double with cnt
10. Double with code
11. Ach <-- A or B
12. Through print
Reference Ach and Bch are the same in unit, the grand total all of both ch's is
printed after printingthe total of each ch. If the units are different, the
grand totals of both ch's are not printed.
Caution
When "Double size" is selected under Print Every Format, only the
first four characters are printed properly due to the print width. Be
careful when selecting the following units.
20:kg/m
3
24:kg•cm 30:kg/cm
2
The count of "Ach <-- A or B" is numbered serially.
(Selection item 11)
Ach and Bch (SIF Ach) input data are all computed as Ach.
Make the unit and decimal place settings of Ach and Bch identical.
Otherwise, totals will not be able to be printed accurately.
If "12. Through print" is selected with no RS-232C interface (option),
"ERROR" is printed, resulting in no selection.
07: Print Every Format
Internal
Ach
Ach input
Bch input
Ach input Bch input
Normal double print
1ch-added double print
computation
Internal
Bch
computation
Internal
Ach
computation