3.8.4. Wiegand output settings 
 ◆ [Ent-] Æ [6] Æ ‘084265’ [Ent] Æ [4] ◆ 
Wiegand Out:0 
0=None 1=26bit 
2=34bit 
  Default setting: ‘0’ 
When this is set to [1], “Site code + user ID” is sent to the Wiegand port of the 
terminal when authentication is done. It can be used only for systems where 
there is a lock controller and the controller is operated by a Wiegand input. This 
is usually set to [0]. 
- If it is set to ‘1’, user ID shall be shorter than 4 digits because “Site code [1 
byte] + user ID [2 bytes]” is transferred.   
- If it is set to ‘2’, user ID shall be shorter than 7 digits because “Site code [1 
byte] + user ID [3 bytes]” is transferred. 
※ this is not effective when a Wiegand-type card reader is used, and set the 
following site code when the setting is higher than ‘1’ 
<Site code> 
(0-255):000 
  Default setting: ‘0’ 
This is only available when Wiegand Out is set to ‘1’ or ‘2’. Enter the site code 
(0-255) to be sent to the Wiegand port together with the user ID  니다. 
Once the setting is complete, press [ENT] to move to the upper menu. 
3.8.5. Terminal initialization 
In the main menu, press [6] to select “6. Device” and then press [6] to select “6. 
Initialize” and the following screen will be appeared: 
1. Init Config 
2. Delete Log 
3. Init Terminal 
  Press [1] for settings initialization,   
press [2] for authentication   
record initialization, 
press [3] for factory initialization. 