Specifications
 AC6000 
TM
 Configuration Manual     80   
UNION COMMUNITY Co., Ltd. 44-3 Hyundai Topics Building, Bangi-dong,   
Songpa-gu, Seoul, Korea 138-050, Tel: 82-2-6488-3000, Fax: 82-2-6488-3099,   
E-Mail:sales@unioncomm.co.kr, http://www.virditech.com 
3.2.7.3.3. Card Reader 
  This section is for display only. When you scan your card the card number of the card will be 
  displayed in this area. This is useful for determining your card number in cases where you do not 
  have a reader for your software when enrolling a user. The number is displayed in hexadecimal 
  or decimal depending on the card number. 
3.2.7.3.4.  Open Too Long (Warning Time) 
The Open Too Long Time is programmable from 00-99 seconds. The default value is 20 seconds. 
If your system is properly connected to the door monitoring inputs on the terminal; and if the door 
lock is opened longer than this time a warning alarm will sound. If 00 is programmed the warning 
alarm will not sound. 
3.2.7.4. Input Settings    
The AC6000 Terminal has four (4) input terminals on the back of the unit. On previous versions 
these were set to perform specific functions. Now the inputs can be programmed for many various 
functions. An external controller, door lock, security system or other device can be connected to 
provide a signal to the AC6000.   