User guide
AC-2100 User Guide    40 
UNIONCOMMUNITY Co., Ltd. / 3F Hyundai Topix Bldg. 44-3 Bangi-dong Songpa-gu   
Seoul, Korea (138-050) 
Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr 
http://www.unioncomm.co.kr 
After selecting a setting value, press [ENT] button to finish authentication 
method setting and move to the upper menu. 
3.5.3. Door Setting 
If [3.Option] is selected at the main menu, the following screen is displayed. 
1. Application 
2. Verify Option 
3. Set Doorlock 
4. Sound Control 
5. LCD Setting 
6. Time Setting 
[ESC][↑][↓][ENT] 
  Select [3.Set Doorlock] for door setting. 
3.5.3.1. Door Open Duration Setting 
◆ At default screen [F2~] Æ [3.Option] Æ [3.Set Doorlock] ◆ 
<Open Duration> 
(00-30):03 
[←] [↑] [↓] [→] 
  Default setting: ‘03’ (Unit: Second) 
This option sets the duration of time until the door is locked again after the 
door is opened through authentication success in the terminal. Strike type 
represents a time when the door is locked again automatically after the door 
is opened through authentication success. In case of dead bolt type and 
automatic door, the door operates regardless of these setting values. 
‘ 
If it is set to ‘00’, door control is not possible. Use ‘00’ setting only when the 
lock is not connected. 
After selecting a setting value, press down [F4] button for a longer period of 
time to continue setting. 
3.5.3.2. Door Open Status Check 
◆ At default screen [F2~] Æ [3.Option] Æ [3.Set Doorlock] Æ [F4~] ◆ 