Problem Possible Cause Corrective Action
Not operating No power to unit Switch in OFF position
Power cord not plugged in completely
Faulty power source
Blown fuse Refer to Troubleshooting Section
Bin A or B will not load
stock
Bin A and B are directly exposed to
sunlight
Reposition the Unit so that Bins A and B are not
directly exposed to sunlight
Offline ONLINE/ENTER button pressed
while SPRITE was Online
Press ONLINE/ENTER button to return Online
Alert condition forced Unit Offline Clear alert condition and press RESET/EXIT button
followed by ONLINE/ENTER
Unit delivers blank
coupons
Stock loaded incorrectly Remove stock and reload with face side down and
staple stub first
Wrong stock type Load direct thermal stock
Contrast adjusted too low for
current stock being used
Adjust darkness using the Adjust Contrast option in
the menu 1-Lightest; 5-Darkest
Print too dark and blurred Contrast adjusted too high for
current stock being used
Adjust darkness using the Adjust Contrast option in
the menu 1-Lightest; 5-Darkest
Stock Light flashing Stock supply depleted
Stock not loaded correctly
Reload stock in depleted bin
Remove and reload stock
Print not aligned correctly
Print misalignment Adjust Top and/or Left Margin using the
corresponding adjust menu option
Unit Jamming Stock left in transport
Drive wheels slipping
Check transport for small piece of stock left in Unit
Use cleaning card Refer to Cleaning Section
Burst Failure Stock damaged and did not burst Remove damaged stock from Unit and press
RESET/EXIT
Burst position incorrect Adjust Burst Position using the Burst Adjust option