Operations Manual

Error Codes
Display Definition Corrective Action
AF (Flashing) Bouncing Airflow Switch Cycling power will not clear error. Start machine and al-
low it to terminate normally. To quickly advance cycle,
set HEAT TIME to 0 and COOL DOWN TIME to 1, then
press START (control may flash "Lr"). Once machine has
cycled, identify and correct problem.
Check airflow switch to ensure that it is properly aligned
and securely mounted in the mounting bracket.
Make sure airflow switch can open and close freely.
Check installation and make sure there is adequate air-
flow.
Make sure exhaust is not blocked.
Clean the lint screen.
Replace airflow switch if inoperative.
AF (Solid) Airflow Switch Closed when Resuming
Cycle
Allow up to 20 seconds for this condition to clear.
Check if airflow switch opens at end of cycle.
Replace airflow switch if inoperative.
Table 14
Electronic OPL Micro Control
OM and RM Control Suffixes
1. To use an Automatic Cycle, press an ON/SELECT pad. Select
HIGH, MEDIUM, MED LOW, LOW or NO HEAT for items
that should not be dried with heat. A light to the left of the se-
lected pad lights up.
HIGH
Temperature 180°F [82°C]
MEDIUM
Temperature 160°F [ 71°C]
MED LOW
Temperature 140°F [60°C]
LOW
Temperature 120°F [49°C]
To use a Time Dry or Custom Cycle, refer to the Programming
Manual.
TMB1483N_SVG
Figure 37
NOTE: Do not press directly on lights or the center
of pad. For proper selection, press on pad slightly
to the right of center. Refer to Figure 38 .
TMB806N_SVG
Figure 38
2. Select REVERSING or NONREVERSING cylinder rotation
setting.
TMB1486N_SVG
REVERSING
Figure 39
3. Press START pad to start tumble dryer.
TMB1485N_SVG
Figure 40
Operating Instructions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
73 Part No: 70457901ENR14