Operations Manual
050 and Classic Line 075 Series Electric Models
Serial Plate Rating
Terminal Block
Connections Re-
quired
Serial Plate Amps Recommended Circuit
Nonre-
versing
Revers-
ing
Breaker
Rating
Wire Size
AWG
[mm
2
]
240V/50Hz/1ph (050 Series
only)
L1, Neutral and Ground 93 95 125A – 1 pole 1 [35]
200-208V/60Hz/3ph L1, L2, L3 and ground 89 88 125A – 3 pole 1 [35]
200V/50Hz/3ph L1, L2, L3 and ground 84 85 125A – 3 pole 1 [35]
230V/50Hz/3ph L1, L2, L3 and ground 73 75 100A – 3 pole 3 [26.7]
240V/50Hz/3ph L1, L2, L3 and ground 79 78 100A – 3 pole 3 [26.7]
240V/60Hz/3ph L1, L2, L3 and ground 79 78 100A – 3 pole 3 [26.7]
380V/50 or 60Hz/3ph L1, L2, L3 and ground 47 48 60A – 3 pole 6 [16]
400-415V/50Hz/3ph L1, L2, L3 and ground 43 44 60A – 3 pole 6 [16]
440V/60Hz/3ph L1, L2, L3 and ground 41 41 50A – 3 pole 6 [16]
480V/60Hz/3ph L1, L2, L3 and ground 38 38 50A – 3 pole 6 [16]
Table 11
Eco Line 075 Series Electric Models
Serial Plate Rating
Terminal Block Con-
nections Required
Serial Plate Amps Recommended Circuit
Nonrevers-
ing
Revers-
ing
Breaker
Rating
Wire Size
AWG
[mm
2
]
200-208V/60Hz/3ph L1, L2, L3 and ground 63 63 80A - 3 pole 4 [25]
240V/60Hz/3ph L1, L2, L3 and ground 56 56 70A - 3 pole 4 [25]
380V/50Hz/3ph L1, L2, L3 and ground 34.3 35.3 45A - 3 pole 8 [10]
380V/60Hz/3ph L1, L2, L3 and ground 32.6 32.6 45A - 3 pole 8 [10]
400-415V/50Hz/3ph L1, L2, L3 and ground 32.3 33.3 40A - 3 pole 8 [10]
440V/60Hz/3ph L1, L2, L3 and ground 28.4 28.4 40A - 3 pole 8 [10]
460-480V/60Hz/3ph L1, L2, L3 and ground 26.9 26.9 35A - 3 pole 8 [10]
Table 12
Electrical Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
61 Part No: 70457901ENR14