Operations Manual

075 Series Gas and Steam Models
Serial Plate Rating
Terminal Block
Connections Re-
quired
Serial Plate Amps Recommended Circuit
Nonre-
versing
Revers-
ing
Breaker
Rating
Wire Size
AWG [mm
2
]
120V/60Hz/1ph L1, Neutral and ground 13.8 N/A 20A – 1 pole 12 [4]
120/208-240V/60Hz/1ph L1, L2, Neutral and ground 13 13 20A – 1 pole 12 [4]
208-240V/60Hz/1ph L1, L2, Neutral and
ground
7.6 N/A 20A – 1 pole 12 [4]
200-208-240V/60Hz/1ph L1, L2 and ground 7.6 N/A 15A – 2 pole 14 [2.5 ]
230-240V/50Hz/1ph L1, Neutral and ground 6.7 7.0 15A – 1 pole 14 [2.5 ]
200-208/240V/60Hz/3ph L1, L2, L3 and ground 3.8 4.3 10A – 3 pole 14 [2.5 ]
200V/50Hz/3ph L1, L2, L3 and ground 3.5 4.5 10A – 3 pole 14 [2.5 ]
230-240V/50Hz/3ph L1, L2, L3 and ground 3.5 4.9 10A – 3 pole 14 [2.5 ]
380V/50 or 60Hz/3ph L1, L2, L3 and ground 1.8 2.1 10A – 3 pole 14 [2.5 ]
400-415V/50Hz/3ph L1, L2, L3 and ground 1.8 2.1 10A – 3 pole 14 [2.5 ]
440V/60Hz/3ph L1, L2, L3 and ground 1.9 2.1 10A – 3 pole 14 [2.5 ]
460-480V/60Hz/3ph L1, L2, L3 and ground 1.9 2.1 10A – 3 pole 14 [2.5 ]
N/A = Not Applicable
Table 9
F75 Gas Models Only
Serial Plate Rating
Terminal Block
Connections Re-
quired
Serial Plate Amps Recommended Circuit
Nonre-
versing
Revers-
ing
Breaker
Rating
Wire Size
AWG [mm
2
]
200-208/240V/60Hz/3ph L1, L2, L3 and ground N/A 6.3 15A – 3 pole 14 [2.5 ]
460-480V/60Hz/3ph L1, L2, L3 and ground N/A 3.1 10A – 3 pole 14 [2.5 ]
N/A = Not Applicable
Table 10
Electrical Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
60 Part No: 70457901ENR14