Operations Manual
Model Gas
Altitude Burner Orifice
New
Rate
feet [me-
ters] No.
inches
[mm] Quantity
Part
Number
Btu/hr.
[Mj/hr.]*
Eco Line 075
Series
Natural Gas
50 Hz
2001-4000
[610-1220]
--- 0.1299 [3.3] 2 44253801 101,200 [107]
4001-6000
[1221-1830]
1/8 0.1250 [3.2] M402489 92,400 [ 97]
6001-8000
[1831-2440]
--- 0.1220 [3.1] 70070903 83,600 [88]
8001-10,000
[2441-3050]
31 0.1200 [3.0] M401017 74,800 [79]
Natural Gas
60 Hz
2001-4000
[610-1220]
28 0.1405 [3.6] M401014 119,600 [126]
4001-6000
[1221-1830]
29 0.1360 [---] M400997 109,200
[115]
6001-8000
[1831-2440]
--- 0.1299 [3.3] 44253801 98,800 [104]
8001-10,000
[2441-3050]
1/8 0.1250 [3.2] M402489 88,400 [93]
F75 Series Natural Gas 2001-4000
[610-1220]
22 0.1570 [4.0] 3 M402996 207,000
[218]
4001-6000
[1221-1830]
24 0.1520 [3.9] M402980 189,000
[199]
6001-8000
[1831-2440]
26 0.1470 [3.7] M401000 171,000
[180]
8001-10,000
[2441-3050]
28 0.1405 [3.6] M401014 153,000
[161]
L.P. Gas 2001-4000
[610-1220]
41 0.0960 [2.4] M401015 225,000
[237]
4001-6000
[1221-1830]
42 0.0935 [2.4] M403017 189,000
[199]
6001-8000
[1831-2440]
43 0.0890 [2.3] M406184 171,000
[180]
8001-10,000
[2441-3050]
44 0.0860 [2.2] M401001 153,000
[161]
Table 7 continues...
Gas Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
51 Part No: 70457901ENR14