Operations Manual
Model Gas
Altitude Burner Orifice
New
Rate
feet [me-
ters] No.
inches
[mm] Quantity
Part
Number
Btu/hr.
[Mj/hr.]*
050 Series Natural Gas 2001-4000
[610-1220]
27 0.1440 [3.7] 2 M400998 119,600
[126]
4001-6000
[1221-1830]
28 0.1405 [3.6] M401014 109,200
[115]
6001-8000
[1831-2440]
29 0.1360 [3.4] M400997 98,800 [104]
8001-10,000
[2441-3050]
30 0.1285 [3.3] M401021 88,400 [93]
L.P. Gas 2001-4000
[610-1220]
43 0.0890 [2.3] M406184 119,600
[126]
4001-6000
[1221-1830]
44 0.0860 [2.2] M401011 109,200
[115]
6001-8000
[1831-2440]
45 0.0820 [2.1] M401027 98,800 [104]
8001-10,000
[2441-3050]
46 0.0810 [2.1] M401003 88,400 [93]
Classic Line
075 Series
Natural Gas 2001-4000
[610-1220]
29 0.1360 [3.4] 3 M400997 151,800
[160]
4001-6000
[1221-1830]
30 0.1285 [3.3] M401021 138,600
[146]
6001-8000
[1831-2440]
1/8 0.1250 [3.2] M402489 125,400
[132]
8001-10,000
[2441-3050]
31 0.1200 [3.0] M401017 112,200
[118]
L.P. Gas 2001-4000
[610-1220]
45 0.0820 [2.1] M401027 165,000
[174]
4001-6000
[1221-1830]
47 0.0785 [2.0] M400999 138,600
[146]
6001-8000
[1831-2440]
47 0.0785 [2.0] M400999 125,400
[132]
8001-10,000
[2441-3050]
48 0.0760 [1.9] M401001 112,200
[118]
Table 7 continues...
Gas Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
50 Part No: 70457901ENR14