Operations Manual
TMB2328N_SVG
4
3
2
1
1. Gas Shut-Off Valve (Ahead of pressure tap) (Shown in
open position) (Not Supplied)
2. Pressure Tap
3. Gas Shut-Off Valve (Shown in closed position) (Not Sup-
plied)
4. Specified Local Inlet Pressure
Figure 15
Specific Conversion Procedures
How to Convert Gas Valve from Regulated to Unregu-
lated
NOTE: Conversion from regulated to unregulated is on-
ly needed when regulated tumble dryers were ordered,
but unregulated tumble dryers were needed.
1. Disconnect electrical power from tumble dryer. Close gas
shut-off valve to tumble dryer. Refer to Figure 15 .
2. Follow instructions in Conversion Kit, Part No. M400763.
NOTE: These kits do not contain any burner orifi-
ces.
3. Replace burner orifice(s) as per Table 1 .
4. If applicable, peel off the appropriate conversion sticker (in-
cluded with tumble dryer) and apply it to the serial plate over
the “ADJUSTED FOR ______ GAS: ______” information.
5. Commission tumble dryer for use.
How to Change Burner Orifice Size
1. Disconnect electrical power from tumble dryer. Close gas
shut-off valve to tumble dryer. Refer to Figure 15 .
2. Remove spud holder. Unscrew spud holder nut near gas valve.
Remove the burner orifice(s) from spud holder. Refer to Fig-
ure 16 .
3. Install the new, correct burner orifice(s). Refer to Figure 17
and Table 1 . Torque each to 9 – 10 Nm.
4. Reinstall spud holder assembly to gas valve, making certain
burner orifice(s) are in line with burner tube opening. Refer to
Figure 17 .
5. Commission tumble dryer for use.
NOTE: Blank burner orifices are Part No. M400995.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
36 Part No: 70457901ENR14